Product Description
This Dust Monitoring Analyzer is an optical instrument designed to measure the concentration of dust or particulate matter suspended in exhaust gas passing through a duct or stack of industrial process.

This Analyzer uses the transmitter and receiver based optical transmission technology, in which a light beam emitted from the transmitter passes across the stack to a receiver, which then measures attenuation in the intensity of the received light.

Increased particulate density in the stack causes variation in amplitude of the signal.

When calibrated against standard reference measurements, the amplitude of this signal relates directly to the particulate concentration in the stack, and can be used to present a reading in mg/m³.

The advantage if Dust Analyzer is that it is significantly less susceptible to drift with time, temperature or dirtying optics, than traditional dust monitors.

Technical Specifications

Make

EIE

Model

EIE/UV500

Analyser Type

Cabinet type and Multiparameter

Measuring Principle

COD, BOD and TSS: UV light absorbance method (Sample scan between 180 to 800nm)
pH: Electrochemical method
PAH (Poly-aromatic hydrocarbons): UV fluorescene method

Measuring range

COD: 0-500 ppm (other higher ranges available upon request)
BOD: 0-200 ppm (other higher ranges available upon request)
TSS: 0-1500 ppm (other range up to 30000ppm available upon request)
pH:0-14 pH
PAH: 0-100 ppm Phenol (equivalent to approx. 0-100 ppm oil with 10% aromatic ratio)

Operating pressure

4 bar with out sampling pump or 1 bar with the sampling pump

Operating Temperature

0oC to 80oC

Operating Flow

0-5L/min

Enclosure protection

IP65, stainless steel with epoxy coating

Communication

RS232 included (Sub-D 9 ways female connector ) with 2 meters cable for PC
USB port included for USB key connection

Memory

5000 records (up to 16 measurement channels) with date and time

Display

Colour TFT LCD resolution: 640x480 pixels with LED backlight

Power supply

90-264V AC 50/60Hz

Cleaning Method

Automatic cleaning

Calibration requirement

Zero calibration: An auto zero is performed at every cleaning cycle.
Span: Factory calibrated. No further adjustment is normally required.

UV source

Xenon Flash lamp

USB port

Yes

Additional features

Automatic zero calibration facility


The UV source is Xenon flash lamp corresponds to more than 10 years of life time with one measurement every minute.


Analyser is cabinet type for easy operation, maintenance and troubleshooting.


Validation of the analyser is possible due to cabinet type design


The patented flow cell allows very high level of suspended solid with out clogging.


USB port is available for recorded measurement download, screen copy function (easy troubleshooting) and software update.

 